|   5-1-specifikacii.html 5.1. Specifications
|  |  Separate parameters are specified also in the text of Head and in case of obligation of their performance are allocated with a bold print.  |  
Cooling system
 
| Characteristic  | Value  |  
|  Volume of cooling liquid   
  | See. Head Routine maintenance 
 |  
|  Settlement pressure of a cover of a radiator, kgf/cm 2 
 |  
|  | 0.6 — 0.98   |  
|  | 9 — 14   |  
|  Temperature of opening of the thermostat, °C   
  | 82   |  
|  Valve stroke of the thermostat, mm   
  | 10 (at 95°С)   |  
Central air
 
| Characteristic  | Value  |  
|  To/in compressor type   
  | Calsonic V6 6-cylinder   |  
|  Coolant type   
  | R-134a   |  
|  Volume of a coolant, ml   
  | 633 — 738   |  
|  Type of refrigerator oil   
  | "S" (No. KLH00-PAGS0)   |  
|  Volume of the refrigerator oil which is filled in at change of components, ml   |  
|  | To fill in in the quantity equal to amount of merged oil   |  
|  | 75  |  
|  | 75   |  
|  | 6   |  
|  | 204   |  
|  Working pressure in system at temperature 30°С and relative humidity of 50 — 70 % (to check not less than 10 minutes later after system start)   
  |  
| 
 Low-pressure head path, kgf/cm 2 
 | 2.0 — 2.8   |  
| 
 High-pressure head path, kgf/cm 2 
 | 14.5 — 19.2   |  
|  Effort of a tension of a belt of a drive of the To/in compressor   |  
| 
 Size of a deflection of a new belt, mm  |  9.0 — 10.0  |  
| 
 Size of a deflection of the belt which was in the use, mm   |  
|  | 9.0 — 11.0   |  
|  | 10.5 — 11.5   |  
|  Location of service valves of the compressor   |  
|  | In the line of a low pressure between the evaporator and the compressor   |  
|  | In the line of a high pressure between the compressor and the condenser   |  
Productivity of To/in system
 
| Temperature of external air, °C  | Temperature on leaving the system, °C  |  
| At relative humidity of 50 — 60 % |  
| 25  | 6 — 9  |  
| 30  | 10 — 13.6  |  
| 35  | 15.2 — 19.5  |  
| 40  | 22.5 — 27.1  |  
| At relative humidity of 60 — 70 % |  
| 25  | 9 — 12.2  |  
| 30  | 13.6 — 17.2  |  
| 35  | 19.5 — 23.7  |  
| 40  | 27.1 — 32.3  |  
Temperature and pressure head characteristics of system
 
| Temperature of external air, °C (at relative humidity of 50 — 70 %)  | Pressure in a high-pressure head path, kgf/cm 2 | Pressure in a low-pressure head path, kgf/cm 2 |  
| 25  | 12.5 — 16.7  
  | 1.8 — 2.6  |  
| 30  | 14.5 — 19.2   | 2.0 — 2.8  |  
| 35  | 16.9 — 22.3   
  | 2.4 — 3.2  |  
| 40  |  19.6 — 25.5  
  | 29. — 3.8  |  
Condition of the double-thread switch
 
| Pressure, kgf/cm 2 
 | System condition | Conductivity between plugs 1 and 2 |  
| Low-pressure head path |  
| Lowering to 1.6 — 2.0  | Off.  | No  |  
| Raising to 1.6 — 2.0  
  | Incl.  
  | Takes place  |  
| High-pressure head path |  
| Lowering to 19 — 23  | Incl.  | Takes place  |  
| Raising to 19 — 23  | Off.  | No  |  
 
 
 | 
 
 
 
 
 
 
 
 
 
 
 
 
 |